 Model Number 139-010 / 65A~300A

Special Feature

  • Provides quick check action
  • Operates using pressure in the pipe
  • Adjustable the speed of opening and closing separately

Booster Pump Control Valve is designed for installation on booster pump's discharge side to prevent starting and stopping pressure surges in the pipeline while the pump starts and stops.
If power failure occurs, the valve immediately closes preventing return flow, regardless of control mode.

Patent

  • Korea Patent No. : 0479297

Specifications

Specifications

Screwed
KSPT(BSP) - NPT Standard

Flanged
10kgf/㎠ - ANSI 150 Standard

Globe

50A(2") ~ 80A(3")

50A(2") ~ 300A(12")

Angle

50A(2") ~ 80A(3")

50A(2") ~ 300A(12")

Operating Pressure

 Specifications

KS D 1513. Class 10

ANSI B 16.42 Class 150

Operating Pressure

0.05~1.5 MPa(0.5~15kg f/㎠)

7~213 PSIG

Media

Temperature :  0°C ~ 80°C  Water, Oil (Order-Made)

Materials

Compartment

Material Options

Body & Cover

Ductile Iron

SSC13

Diaphragm Washer & Disc

Cast Iron

SSC13

Cover Plug & Bearing

Brass

STS304

Shaft & Seat

STS304

Diaphragm

Nylon reinforced N.R

Disc Seal

N.R

Note
NSF/ANSI Standard 61 Epoxy Coating standard
Nylon 11 Coating available (Rilsan Coating) : optional

Solenoid Control Valve Specifications

Voltage

  24, 110, 220 AC 60Hz or 50Hz / 12, 24 DC

Operating Pressure

  1.5 MPa (213 PSIG)

Coil Insulation

  Coil Insulation Class B(Standard) H(Optional)

Power Supply

  AC 8 Watts / DC 12 Watts

Description

Item

Description

1

BALEM 130 (Basic Valve)

2

Strainer

3

Cock Valve

4

Suttle Valve

5

3-Way Solenoid control Valve

6

Flow Control Valve

7

3-Way Solenoid control Valve

8

Flow Control Valve

9

Cock Valve

10

Flow Clean Strainer



Control Diagram

Typical Applications

Sequence Of Operation

Pump Off

With pump off, static line pressure is transmitted through strainer "F"→shuttle Valve "B"→solenoid valve 1→speed control "D"→the chamber above the diaphragm, thus holding the valve closed.
If power failure occurs, the valve closes immediately to prevent reverse flow, regardless of control mode.

Starting Cycle

Starting switch closes, pump starts, solenoid control valve 1 energizes and shifts allowing fluid from upper diaphragm chamber to drain to atmosphere.
High pressure fluid from pump enters strainer "A"→shuttle valve "B"→solenoid valve 2→speed control valve "C"→High pressure fluid is transmitted to the lower diaphragm chamber and opens the valve slowly.

Stopping Cycle

Starting switch opens, solenoid control 2 de-energizes and shifts, pump continues to run. High Pressure fluid from the pump is directed above the diaphragm, applying force to close the valve. The valve closes slowly as fluid from the lower diaphragm chamber is gradually released to atmosphere through speed control "C" and solenoid valve 2. When the valve closes fully, the limit switch "E " shuts off the pump by electrical signal.

Dimensions

Valve Size (mm) 

50

80

100

150

200

250

300

 When Ordering,
       Please Specify

  1. Model No.
  2. Valve Size
  3. Pattern : Globe or Angle
  4. Working Pressure
  5. Screwed or Flanged
  6. Desired Materials
  7. Desired Options
  8. Solenoid Valve Specification

 A Screwed

238

318

-

-

-

-

-

 AA 10kgf/㎠

238

305

381

508

645

756

864

 B

78

93

105

140

165

200

223

 Cmax

200

240

275

375

462

536

623

 Dmax

157

179

206

284

351

398

461

 ΦE

140

165

208

326

408

497

562

 F Screwed

119

140

-

-

-

-

-

 FF 10kgf/㎠

119

152

191

254

322

378

432

 G Screwed

83

114

-

-

-

-

-

 GG 10kgf/㎠

83

102

127

152

203

219

349

Weight kgs

14

26

41

95

169

268

492

 

Valve Size (inches) 

2

3

4

6

8

10

12

 A Screwed

9.38

12.50

-

-

-

-

-

 AA 150 ANSI

9.38

12.00

15.00

20.00

25.38

29.75

34.00

 B

3.00

3.75

4.50

5.50

6.75

8.00

9.70

 Cmax

7.88

9.45

10.83

14.77

14.25

21.10

24.53

 Dmax

6.19

7.05

8.12

11.19

13.82

15.67

18.15

 ΦE

5.52

6.50

8.19

12.83

16.07

19.57

22.13

 F Screwed

4.69

6.25

-

-

-

-

-

 FF 150 ANSI

4.69

6.00

7.50

10.00

12.69

14.88

17.00

 G Screwed

3.25

4.50

-

-

-

-

-

 GG 150 ANSI

3.25

4.00

5.00

6.00

8.00

8.62

13.75

Weight  lbs

31

57

90

210

373

591

1085

Installation

  • Before installation, flush to clean pipeline.
  • Provide adequate clearance for servicing.
  • Arrow on valve body must match actual flow direction in pipe.
  • Preferred valve installation, - upright, for horizontal position; others acceptable.
  • Install isolation valves on both sides of control valve.
  • For assistance, please contact our office or factory for specific recommendations.